Silicone transfer happens when the release coating is not fully cured or is applied too heavily, leaving free silicone that migrates onto the adhesive face and reduces its bond strength; it is detected by a low residual-adhesion result. Contamination during coating or incompatible chemistry can also cause it. A correctly produced liner shows high residual adhesion (the adhesive keeps nearly all its strength) and no smear. If transfer is suspected, retain the roll and batch label, run a subsequent-adhesion test against the specification, and contact the supplier with the measured data for investigation.